Project Specific Input: Entered on a project-by-project basis.
Boiler Manufacturer Economizer Will Be Installed On: Project Specific Input
Select Manufacturer
--- Atmospheric Commercial Boilers ---
To be Advised
--- Firetubes (Scotch Marine) ---
Burnham
Columbia
Continental
Cleaver-Brooks
Cleaver-Brooks LE
Cyclotherm
Donlee
Eclipse
English Boiler
Hurst
Industrial
Johnston
Kewanee
Myrggo
North American
Sellers
Superior
Triad Boiler Systems
York-Shipley
Unlisted Firetube
--- Flextube Watertubes ---
Bryan
English BTBF
Unilux Flextube
Universal Boiler Works
Unlisted Flextube
--- Industrial Watertubes (D-A-O-S Types) ---
ABCO
Aalborg
B & W
Bigelo
Cleaver-Brooks D-Type
Clayton
Combustion Engineering
English Boiler
Erie City
Foster Wheeler
Fulton
Indeck-Keystone
Keeler
Murry Trane
Nebraska
Rentech
Unilux
Union Iron Works
Vapower
Victory Energy
Volcano
Zurn
Unlisted Industrial Watertube
We recommend you enter the manufacturer of the boiler if known as some boilers, primarily firetube boilers,
have a lower tolerance for flue gas backpressure. Not selecting any specific manufacturer will result
in the use of default data for the boiler type selected.
Existing Boiler Efficiency:
You can change the efficiency of the exisiting boiler system. The default is 81%. The fuel
mass flow rate calculations are based on this number so should not only be changed with care
and knowledge.
Select Current Boiler Efficiency:
0.81
0.79
0.78
0.75
0.72
0.70
0.65
0.80
0.82
0.83
0.84
Part-Load Flue Gas Temperature Input: Project Specific Input
The AutoPick software will automatically reduce flue gas temperature for typical applications. If you
wish to enter specific flue gas temperatures at part-load firing rates you may do so below. NOTE ! If you
do not want to enter other gas temperatures then leave these cells blank !
Gas Temperature at 100% Load: Entered Above in REQUIRED section
Gas Temperature at 75% Load: deg F
Gas Temperature at 50% Load: deg F
Gas Temperature at 25% Load: deg F
Burner Flue Gas Recirculation Rate: Project Specific Input
Enter the FGR rate only if your burner utilizes FGR and only if the FGR connection to the burner is downstream of the economizer. If your burner does not
use any FGR then leave this cell blank. Typical Low NOx burners run 5% to 15%. Standard burners have no FGR
so leave cell blank.
Enter Blowdown Rate (%):
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Project Specific Input
This is the percent continuous (surface) blowdown. Enter if known.
Enter Fuel Price ($/mbtu):
8.00
8.25
8.50
8.75
9.00
9.25
9.50
9.75
10.00
10.25
10.50
10.75
11.00
11.25
11.50
11.75
12.00
12.25
12.50
12.75
13.00
13.25
13.50
13.75
14.00
14.25
14.50
14.75
15.00
15.25
15.50
15.75
16.00
16.25
16.50
16.75
16.00
16.25
16.50
16.75
17.00
17.25
17.50
17.75
18.00
18.25
18.50
18.75
19.00
19.25
19.50
19.75
20.00
20.25
20.50
20.75
21.00
21.25
21.50
21.75
22.00
22.25
22.50
22.75
4.00
4.25
4.50
4.75
5.00
5.25
5.50
5.75
6.00
6.25
6.50
6.75
7.00
7.25
7.50
7.75
Project Specific Input
Select the price of natural gas in dollars per million btu's.
Enter Annual hours of Operation: Project Specific Input
There are a total of 8,760 hours in one year
8750
1
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
6000
6500
7000
7500
8000
8500
At 100% Firing
1
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
6000
6500
7000
7500
8000
8500
At 75% Firing
1
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
6000
6500
7000
7500
8000
8500
At 50% Firing
1
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
6000
6500
7000
7500
8000
8500
At 25% Firing
These hours will be reflected in each of the four load performance runs
Unit Fin Count: Project Specific Input
5 Fins per Inch - Gas Firing Only
4 Fins per Inch - Gas and Consistant #2 Oil Firing
3 Fins per Inch - Fuel Oil Firing
You may select 5 fins per inch if your plant fires gas with a #2 oil for
standby use of less than one week annually. 4 fins for constand #2 oil firing, and
3 fins for heavy oil, #6, or other dirty fuels. If unsure leave at 5 fins.